Skip to product information
1 of 6

Hanna Instruments Marine Master Multiparameter Photometer - HI97115

Hanna Instruments Marine Master Multiparameter Photometer - HI97115

Regular price $739.00
Regular price Sale price $739.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
People are viewing this right now

Low stock: 1 left

, Delivery by Mar 17, 2025

Shipping & Returns

Enjoy free shipping on orders over $299! T&C's Apply!

We ship all orders within 5-10 business days!

View full details
  • The HI97115 is a compact and versatile Marine multiparameter photometer designed to accurately determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI97115 is suitable for field and bench measurements.

    Marine, Saltwater Aquariums, Aquaculture

    Precise and advanced LED optical system

    The HI97115 can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.

    • Precise and advanced LED optical system
    • Waterproof and floating IP67 meter design
    • Meter validation using certified CAL Check™ cuvettes
    • Includes auto data logging features to easily record up to 200 water testing results
    • On-screen tutorial mode guides users step-by-step through the measurement process
    • Option to assign locations to logged readings
    • Positive-locking system ensures that the cuvettes are placed into the holder in the same position every time
    • Future compatibility with Hanna Cloud

    Innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

    LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

    diag

    CAL Check™ Validation

    Hanna’s exclusive CAL Check™ feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Check™ standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.

    Tutorial mode can be enabled or disabled from the setup menu.

    On-Screen Tutorials

    The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents, and quantities.

    Tank Selection And Multiple Reading Locations Management

    Users can edit up to 25 different tanks, correlate reading location to any location from the list so that logged data is linked to its reading location.

    Data Logging

    Missed a measurement? No need to worry because your photometer will automatically log the last 200 measurements. The results can be viewed instantly using the Log Recall Menu.


    Advanced Optical System

    A Light Emitting Diode (LED) provides more light while using less power and a narrow band interference filter results in more accurate and repeatable readings.

    Large Cuvette Size

    The 25-mm path length cuvette allows light to pass though more of the sample ensuring accurate measurements even in low-absorbance samples.

    Positive Locking System

    Cuvettes are placed into the holder in the same position every time by ensuring that the notch on the cap is positioned securely in the cell’s groove.

    Portable Design

    Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle, day or night. The supplied AA batteries provide life for more than 800 measurements.


    Each HI97115 Is Supplied With:

    • Sample cuvette (2 pcs.)
    • Sample cap (2 pcs.)
    • Alkaline batteries: 1.5V AA (3 pcs.)
    • Instrument quality certificate
    • A quick reference guide with instructions for manual download

    Each HI97115C (Meter With Kit) Is Supplied With:

    • Sample cuvette (2 pcs.)
    • Sample cuvette cap (2 pcs.)
    • Marine pH reagent, 30 mL dropper (1 pc.)
    • Marine Alkalinity reagent, 30 mL (1 pc.)
    • Marine Ammonia starter kit – reagent A, 30 mL dropper (1 pc.)
    • Marine Ammonia starter kit – reagent B and C (reagent for 25 tests, each)
    • Marine Calcium starter kit – reagent A, 30 mL (1 pc.)
    • Marine Calcium starter kit – reagent B starter kit (reagent for 25 tests)
    • Marine Magnesium starter kit – reagent A, 120 mL bottle (1 pc.)
    • Magnesium indicator reagent (for 25 tests)
    • Marine Nitrate High Range starter kit (reagent for 25 tests)
    • Marine Nitrite Ultra Low Range starter kit (reagent for 25 tests)
    • Marine Phosphate Ultra Low Range starter kit (reagent for 25 tests)
    • 1 mL graduated syringe with tip (2 pcs.)
    • Minipipette with tip (1 pc.)
    • 3 mL Pasteur pipette (2 pcs.)
    • 1.5V AA Alkaline batteries (3 pcs.)
    • Cloth for wiping cuvettes
    • Scissors
    • Instrument quality certificate
    • A quick reference guide with instructions for manual download

    Specifications

    SKU HI97115-web
    Name Marine Master Waterproof Wireless Multiparameter Photometer | HI97115
    Marine pH Range 6.3 to 8.6 pH
    Marine pH Resolution 0.1 pH
    Marine pH Accuracy ±0.2 pH of reading at 25 °C
    Marine pH Method Colorimetric Adaptation of the Phenol Red Method
    Marine pH LED 525 nm
    Marine Alkalinity Range 0.0 to 20.0 dKH
    Marine Alkalinity Resolution 0.1 dKH
    Marine Alkalinity Accuracy ±0.3 dKH ±5 % of reading at 25 °C
    Marine Alkalinity Method Colorimetric Method
    The reaction causes a distinctive range of colors from yellow to greenish blue to develop.
    Marine Alkalinity LED 610 nm
    Marine Ammonia Range 0.00 to 2.50 ppm (as NH₃)
    Marine Ammonia Resolution 0.01 ppm
    Marine Ammonia Accuracy ±0.05 ppm ±5% of reading at 25 °C
    Marine Ammonia Method Adaptation of the Salicylate Method The reaction between Ammonia and Ammonium and the reagent causes a blue-green tint in the sample.
    Marine Ammonia LED 610 nm
    Marine Calcium Range 200 to 600 ppm
    Marine Calcium Resolution 1 ppm
    Marine Calcium Accuracy ±6% of reading at 25 °C
    Marine Calcium Method Adaptation of the Zincon Method
    Marine Calcium LED 610 nm
    Marine Magnesium Range 1000 to 1800 ppm (as Mg2+)
    Marine Magnesium Resolution 5 ppm
    Marine Magnesium Accuracy ±5% of reading at 25 °C
    Marine Magnesium Method Adaptation of the Colorimetric EDTA Method using calmagite indicator
    The reaction between magnesium and the reagents causes a blue to violet tint in the sample.
    Marine Magnesium LED 610 nm
    Marine Nitrate LR Range 0.00 to 5.00 ppm (as NO₃–)
    Marine Nitrate LR Resolution 0.01 ppm
    Marine Nitrate LR Accuracy ±0.25 ppm ±2% of reading at 25 °C
    Marine Nitrate LR Method Zinc Reduction Method
    The reaction between nitrate and the reagent causes a pink tint in the sample.
    Marine Nitrate LR LED 525 nm
    Marine Nitrate HR Range 0.0 to 75.0 ppm (as NO₃–)
    Marine Nitrate HR Resolution 0.1 ppm
    Marine Nitrate HR Accuracy ±2.0 ppm ±5% of reading at 25 °C
    Marine Nitrate HR Method Zinc Reduction Method
    The reaction between nitrate and the reagent causes a pink tint in the sample.
    Marine Nitrate HR LED 525 nm
    Marine Nitrite ULR Range 0 to 200 ppb (as NO₂–-N)
    Marine Nitrite ULR Resolution 1 ppb
    Marine Nitrite ULR Accuracy ±10 ppb ±4% of reading at 25 °C
    Marine Nitrite ULR Method Adaptation of the EPA Diazotization Method 354.1
    The reaction between nitrite and the reagent causes a pink tint in the sample.
    Marine Nitrite ULR LED 525 nm
    Marine Phosphate ULR Range 0.00 to 0.90 ppm
    Marine Phosphate ULR Resolution 0.01 ppm
    Marine Phosphate ULR Accuracy ±0.02 ppm ±5% of reading at 25 °C
    Marine Phosphate ULR Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 20thEdition, Ascorbic Acid Method
    Marine Phosphate ULR LED 610 nm
    Measurement System Light source LED
    Measurement System Bandpass filter wavelength 525 nm & 610 nm
    bandwidth 8 nm wavelength accuracy ±1.0 nm
    Measurement System Light detector silicon photocell
    Measurement System Cuvette Type round 24.6 mm diameter (22 mm inside diameter)
    Additional Specifications Auto logging 200 readings
    Additional Specifications Display 128 x 64 pixel B/W LCD with backlight
    Additional Specifications Auto-off after 15 minutes of inactivity (30 minutes before a READ measurement)
    Additional Specifications Battery type / Life alkaline 1.5 V AA (3) / > 800 measurements (without backlight)
    Additional Specifications Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
    Additional Specifications Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)
    Additional Specifications Weight 380 g (13.4 oz.); with batteries
    Additional Specifications Casing IP67 rating, floating

     

    Manuals

  • Shipping:
    ⦁ Processing time usually takes 1 -2 business days.
    ⦁ Delivery is generally 5-10 business days however, this may vary depending on the warehouse location, shipping location, biosecurity and factors outside of our control.
    Returns:
    ⦁ See our Returns & Exchange Policy

  • Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)