The Kamoer ATO One is a smart water replenishing device that requires only the sensor and the refill pump to be installed. It can be used after power-on without setting any parameters. Includes 1 optical level sensor and 1 float level sensor.
The optical level sensor is used to monitor the water level to determine whether water needs to be replenished. The float level sensor is used to prevent overflow.
An optional float level sensor is available to monitor the freshwater reservoir for water shortage.
The ATO One is rich in status indicators. When the Anti-overflow Sensor or overtime, the refill pump is not inserted or the freshwater reservoir is short of water, the ATO One will have an indicator light and a buzzer alarm.
FEATURES:
Small and compact
Suitable for nano/medium aquariums
Optical sensor for keeping water level stable
Float level sensor for preventing overflow
Very easy to install and adjust with magnetic bracket
Audible and LED light alarm
Submersible pump for meeting the needs of freshwater reservoir
Optional float level sensor for detecting if the freshwater reservoir is empty
INCLUDES:
1 x ATO One controller
1 x Optical Bracket (large mouth)
1 x Float Bracket (small mouth)
4 x Plastic magnet
1 x Power adapter
1 x DC refill pump
1 x Tube holder
1 x Siphon break
1 x PVC tube 1m
Installation, use note.
STEP 1: Install the optical sensor (S1) at the normal water level line and use it as a water fill sensor. Note that the optical level sensor should be kept away from areas with air bubbles, otherwise it will be disturbed causing misjudgment.
STEP 2: Install the optical sensor (S3) above the normal water level line and use it as an overflow prevention sensor. If the water level reaches this position, it means that the fill water optical sensor (S1) has failed and the equipment will alarm and force the fill water pump to stop working.
STEP 3: Connect the pipeline (charge pump - anti-syphon connector - water pipe holder). Be careful to install the anti-syphon fitting inside the recharge bucket and make sure that it is always above the recharge bucket level, if the recharge bucket level is not above the anti-syphon fitting, it will not prevent the siphoning phenomenon; the hose outlet must be above the bottom/main tank level.
STEP 4: Plug the charge pump into the Pump connector. The anti-burnout sensor on the charge pump should be kept up so that it can detect and alert you when the charge bucket is running low and prevent air from entering the submersible pump.
STEP 5: Plug the power adapter into the DC12V connector and power up the power adapter.